site stats

Constrained polyethylene

WebThe Trident® Constrained Acetabular Insert is designed specifically for the Stryker UHR® bipolar head. The bipolar head is preassembled in the insert and securely retained by a … WebNon-constrained polyethylene acetabular liner; RingLoc® RX90®-2 Hip System - 00887868342370. No Description Company Name: Biomet Orthopedics, LLC Version or Model: 11-105940 Commercial Distribution Status: In Commercial Distribution Device IDs: 00887868342370 (Primary) Device Sizes:

NexGen® Legacy® Constrained Condylar Knee (LCCK)

WebAug 4, 2015 · Aug 4, 2015. #1. My physician is asking what code (s) are appropriate for a revision of the acetabulum and the femoral head. He also wants to know the code (s) for revision polyethelene liner and femoral. head. I said 27134 for the acetabulum and the femoral head. 27134-52 for the polyethelene liner and femoral head. Am I correct ? WebAug 28, 2024 · Dissociation of the polyethylene liner from the acetabular shell is a rare but catastrophic complication of total hip arthroplasty (THA). There have been reports of polyethylene liner dissociation (PLD) as well as ceramic liner dissociation (CLD) in the literature. ... The polyethylene was revised and a constrained liner was used instead … harry bluestone saxaboogie https://allproindustrial.net

Survivorship of constrained polyethylene inserts in …

Webpolyethylene – our high-performing compression-molded standard polyethylene and Longevity® Crosslinked Polyethylene. Zimmer has a documented history of more than 20 years of clinical success with Through compression-molded polyethylene.15 It addresses the five key factors that impact polyethylene performance: material, processing, design, Webtrabecular surface allows for long term biologic fixation. Cruciate-Retaining (CR) Design. Design. minimally constrained prosthesis that depends on an intact PCL to provide … WebThe Global Unique Device Identification Database (GUDID) contains key device identification information submitted to the FDA about medical devices that have Unique Device Identifiers (UDI). harry bloomfield montreal

AccessGUDID - biomet

Category:Acetabular liner dissociation: A case report and review of the ...

Tags:Constrained polyethylene

Constrained polyethylene

Factors Affecting Wear of Constrained Polyethylene Tibial

WebSep 1, 1999 · The internal microstructure of a high performance polyethylene fiber, both as received and after heating, has been investigated by electron microscopy following … WebHip. At DePuy Synthes, we’re on a mission to revolutionize hip replacement and reconstruction. By creating class-leading implants, technique-inclusive offerings, and innovative technologies, we enable surgeons to develop customized solutions for every patient. Our mission is to Keep People Moving, and we want to ensure that the hundreds …

Constrained polyethylene

Did you know?

WebAbstract. Background: Wear in posterior-stabilized (PS) polyethylene tibial inserts depends on component position, limb alignment, and ligament balancing. Valgus-varus constrained (VVC) inserts are likely to be affected similarly. We aimed to compare wear characteristics of VVC and PS inserts and identify associated factors. WebJul 8, 2024 · To prevent further infection, the surgeon might replace part of a hip replacement component, such as the polyethylene liner and/or the prosthetic head, coded with 27137 Revision of total hip arthroplasty; acetabular component only, with or without autograft or allograft and modifier 52 Reduced services. (Modifier 52 indicates the full ...

Webconstrained-geometry catalysts (CGCs), which have been evaluated for the preparation of a wide array of ethylene/ a-olefin copolymers possessing unique materials properties.[2] The catalyst precursor or procatalyst (see Scheme 1) con-tains a group IV metal, preferably titanium, which can be acti-vated either as the TiIV dialkyl or TiII diene ... WebConstraint implies a restriction of rotational or translational movement, which can be achieved with a linked or nonlinked implant design. An example of a modern linked …

WebThe Global Unique Device Identification Database (GUDID) contains key device identification information submitted to the FDA about medical devices that have Unique Device Identifiers (UDI). WebAntioxidant protection eliminates the need to remelt the polyethylene, leading to an improvement in strength in comparison to highly crosslinked polyethylene. 9. The vitamin E in Vivacit-E HXPE prevents oxidation, resulting in mechanical strength that is retained after accelerated aging for more than 16 times the 2-week industry standard test ...

http://polymer.chem.cmu.edu/~kmatweb/2000/December_00/Adv%20Mater/metallocenes.pdf

WebJan 12, 2024 · There are many designs in use, but broadly speaking, TKA is characterized by the degree of constraint, polyethylene spacer fixation, and posterior cruciate … harry blu\u0027s ginWebBackground: Varus-valgus constrained (VVC) inserts are used in primary total knee arthroplasty (TKA) when stability cannot be achieved with a traditional insert. Concern … harry blows up aunt margeWebMar 26, 2024 · Constraints on the supplies of their raw materials — especially polyethylene (PE), polypropylene (PP), and monoethylene (MEG) — are leading to factory shutdowns, sharp price increases, and ... charity adjectiveWebJan 6, 2024 · Polyethylene liner (ie "poly") is the most common material type for the acetabular liner, however, ceramic or metal are also available. The Acetabular Shell provides the base for bony ingrowth, while the liner … harry b mackloweWebKim YH, Kim JS. Revision total knee arthroplasty with use of a constrained condylar knee prosthesis. J Bone Joint Surg Am. 2009;91(6):1440-1447. Young-Hoo, K., et al. Long-Term Clinical Outcomes and Survivorship of … harry bliss comics kingdomWebDec 19, 2024 · The 3 polyethylene options used in this study were the CR, PS, and MC. Given the limited use at our institution, UC inserts were excluded from the study. Patients receiving a constrained PS insert were excluded as … harry b macklowes son william s mackloweWebTrident. Acetabular Shell Systems. Feel confident you can meet the needs of each patient with the versatility of the Trident Acetabular Shell offerings, all of which can be used with … charityadvantage.com